RemotePing




Option Explicit
Public Const IP_STATUS_BASE = 11000
Public Const IP_SUCCESS = 0
Public Const IP_BUF_TOO_SMALL = (11000 + 1)
Public Const IP_DEST_NET_UNREACHABLE = (11000 + 2)
Public Const IP_DEST_HOST_UNREACHABLE = (11000 + 3)
Public Const IP_DEST_PROT_UNREACHABLE = (11000 + 4)
Public Const IP_DEST_PORT_UNREACHABLE = (11000 + 5)
Public Const IP_NO_RESOURCES = (11000 + 6)
Public Const IP_BAD_OPTION = (11000 + 7)
Public Const IP_HW_ERROR = (11000 + 8)
Public Const IP_PACKET_TOO_BIG = (11000 + 9)
Public Const IP_REQ_TIMED_OUT = (11000 + 10)
Public Const IP_BAD_REQ = (11000 + 11)
Public Const IP_BAD_ROUTE = (11000 + 12)
Public Const IP_TTL_EXPIRED_TRANSIT = (11000 + 13)
Public Const IP_TTL_EXPIRED_REASSEM = (11000 + 14)
Public Const IP_PARAM_PROBLEM = (11000 + 15)
Public Const IP_SOURCE_QUENCH = (11000 + 16)
Public Const IP_OPTION_TOO_BIG = (11000 + 17)
Public Const IP_BAD_DESTINATION = (11000 + 18)
Public Const IP_ADDR_DELETED = (11000 + 19)
Public Const IP_SPEC_MTU_CHANGE = (11000 + 20)
Public Const IP_MTU_CHANGE = (11000 + 21)
Public Const IP_UNLOAD = (11000 + 22)
Public Const IP_ADDR_ADDED = (11000 + 23)
Public Const IP_GENERAL_FAILURE = (11000 + 50)
Public Const MAX_IP_STATUS = 11000 + 50
Public Const IP_PENDING = (11000 + 255)
Public Const PING_TIMEOUT = 200
Public Const WS_VERSION_REQD = &H101
Public Const WS_VERSION_MAJOR = WS_VERSION_REQD \ &H100 And &HFF&
Public Const WS_VERSION_MINOR = WS_VERSION_REQD And &HFF&
Public Const MIN_SOCKETS_REQD = 1
Public Const SOCKET_ERROR = -1
Public Const MAX_WSADescription = 256
Public Const MAX_WSASYSStatus = 128
Public Type ICMP_OPTIONS
Ttl As Byte
Tos As Byte
Flags As Byte
OptionsSize As Byte
OptionsData As Long
End Type
Dim ICMPOPT As ICMP_OPTIONS
Public Type ICMP_ECHO_REPLY
Address As Long
status As Long
RoundTripTime As Long
DataSize As Integer
Reserved As Integer
DataPointer As Long
Options As ICMP_OPTIONS
Data As String * 250
End Type
Public Type HOSTENT
hName As Long
hAliases As Long
hAddrType As Integer
hLen As Integer
hAddrList As Long
End Type
Public Type WSADATA
wVersion As Integer
wHighVersion As Integer
szDescription(0 To MAX_WSADescription) As Byte
szSystemStatus(0 To MAX_WSASYSStatus) As Byte
wMaxSockets As Integer
wMaxUDPDG As Integer
dwVendorInfo As Long
End Type
Public Declare Function IcmpCreateFile Lib "icmp.dll" () As Long
Public Declare Function IcmpCloseHandle Lib "icmp.dll" _
(ByVal IcmpHandle As Long) As Long
Public Declare Function IcmpSendEcho Lib "icmp.dll" _
(ByVal IcmpHandle As Long, _
ByVal DestinationAddress As Long, _
ByVal RequestData As String, _
ByVal RequestSize As Integer, _
ByVal RequestOptions As Long, _
ReplyBuffer As ICMP_ECHO_REPLY, _
ByVal ReplySize As Long, _
ByVal Timeout As Long) As Long
Public Declare Function WSAGetLastError Lib "WSOCK32.DLL" () As Long
Public Declare Function WSAStartup Lib "WSOCK32.DLL" _
(ByVal wVersionRequired As Long, _
lpWSADATA As WSADATA) As Long
Public Declare Function WSACleanup Lib "WSOCK32.DLL" () As Long
Public Declare Function gethostname Lib "WSOCK32.DLL" _
(ByVal szHost As String, _
ByVal dwHostLen As Long) As Long
Public Declare Function gethostbyname Lib "WSOCK32.DLL" _
(ByVal szHost As String) As Long
Public Declare Sub RtlMoveMemory Lib "kernel32" _
(hpvDest As Any, _
ByVal hpvSource As Long, _
ByVal cbCopy As Long)
Public Function GetStatusCode(status As Long) As String
Dim msg As String
Select Case status
Case IP_SUCCESS: msg = "ip success"
Case IP_BUF_TOO_SMALL: msg = "ip buf too_small"
Case IP_DEST_NET_UNREACHABLE: msg = "ip dest net unreachable"
Case IP_DEST_HOST_UNREACHABLE: msg = "ip dest host unreachable"
Case IP_DEST_PROT_UNREACHABLE: msg = "ip dest prot unreachable"
Case IP_DEST_PORT_UNREACHABLE: msg = "ip dest port unreachable"
Case IP_NO_RESOURCES: msg = "ip no resources"
Case IP_BAD_OPTION: msg = "ip bad option"
Case IP_HW_ERROR: msg = "ip hw_error"
Case IP_PACKET_TOO_BIG: msg = "ip packet too_big"
Case IP_REQ_TIMED_OUT: msg = "ip req timed out"
Case IP_BAD_REQ: msg = "ip bad req"
Case IP_BAD_ROUTE: msg = "ip bad route"
Case IP_TTL_EXPIRED_TRANSIT: msg = "ip ttl expired transit"
Case IP_TTL_EXPIRED_REASSEM: msg = "ip ttl expired reassem"
Case IP_PARAM_PROBLEM: msg = "ip param_problem"
Case IP_SOURCE_QUENCH: msg = "ip source quench"
Case IP_OPTION_TOO_BIG: msg = "ip option too_big"
Case IP_BAD_DESTINATION: msg = "ip bad destination"
Case IP_ADDR_DELETED: msg = "ip addr deleted"
Case IP_SPEC_MTU_CHANGE: msg = "ip spec mtu change"
Case IP_MTU_CHANGE: msg = "ip mtu_change"
Case IP_UNLOAD: msg = "ip unload"
Case IP_ADDR_ADDED: msg = "ip addr added"
Case IP_GENERAL_FAILURE: msg = "ip general failure"
Case IP_PENDING: msg = "ip pending"
Case PING_TIMEOUT: msg = "ping timeout"
Case Else: msg = "unknown msg returned"
End Select

GetStatusCode = CStr(status) & " [ " & msg & " ]"

End Function

Public Function HiByte(ByVal wParam As Integer)
HiByte = wParam \ &H100 And &HFF&
End Function

Public Function LoByte(ByVal wParam As Integer)
LoByte = wParam And &HFF&
End Function

Public Function Ping(szAddress As String, ECHO As ICMP_ECHO_REPLY) As Long
Dim hPort As Long
Dim dwAddress As Long
Dim sDataToSend As String
Dim iOpt As Long

sDataToSend = "Echo This"
dwAddress = AddressStringToLong(szAddress)

hPort = IcmpCreateFile()

If IcmpSendEcho(hPort, _
dwAddress, _
sDataToSend, _
Len(sDataToSend), _
0, _
ECHO, _
Len(ECHO), _
PING_TIMEOUT) Then

'il ping ha avuto esito positivo

'lo stato sara' 0

'

'.RoundTripTime e' il temp in ms necessari al completamento

' del ping,

'.Data contiene i dati ritornati (NULL terminated)

'.Address e' l'indirizzo IP dell'host che ha effettivamente risposto

'.DataSize e' la dimensione della stringa contenuta in .Data

Ping = ECHO.RoundTripTime
Else: Ping = ECHO.status * -1
End If
Call IcmpCloseHandle(hPort)
End Function

Function AddressStringToLong(ByVal tmp As String) As Long
Dim i As Integer
Dim parts(1 To 4) As String
i = 0
'dobbiamo estrarre ogni singola parte dell'inidirizzo

'123.456.789.123, le quali sono separate da un punto (.)

While InStr(tmp, ".") > 0
i = i + 1
parts(i) = Mid(tmp, 1, InStr(tmp, ".") - 1)
tmp = Mid(tmp, InStr(tmp, ".") + 1)
Wend
i = i + 1
parts(i) = tmp
If i <> 4 Then
AddressStringToLong = 0
Exit Function
End If
'crea il valore long dal valore esadecimale delle stringe estratte sopra

AddressStringToLong = Val("&H" & Right("00" & Hex(parts(4)), 2) & _
Right("00" & Hex(parts(3)), 2) & _
Right("00" & Hex(parts(2)), 2) & _
Right("00" & Hex(parts(1)), 2))
End Function

Public Function SocketsCleanup() As Boolean
Dim X As Long
X = WSACleanup()
If X <> 0 Then
MsgBox "Errore Windows Sockets " & Trim$(Str$(X)) & _
" generato in Cleanup.", vbExclamation
SocketsCleanup = False
Else
SocketsCleanup = True
End If
End Function

Public Function SocketsInitialize() As Boolean
Dim WSAD As WSADATA
Dim X As Integer
Dim szLoByte As String, szHiByte As String, szBuf As String
X = WSAStartup(WS_VERSION_REQD, WSAD)
If X <> 0 Then
MsgBox "Windows Sockets per ambienti Windows a 32 bit " & _
"l'ambiente non sta rispondendo in modo positivo."
SocketsInitialize = False
Exit Function
End If
If LoByte(WSAD.wVersion) < WS_VERSION_MAJOR Or _
(LoByte(WSAD.wVersion) = WS_VERSION_MAJOR And _
HiByte(WSAD.wVersion) < WS_VERSION_MINOR) Then
szHiByte = Trim$(Str$(HiByte(WSAD.wVersion)))
szLoByte = Trim$(Str$(LoByte(WSAD.wVersion)))
szBuf = "Windows Sockets Version " & szLoByte & "." & szHiByte
szBuf = szBuf & " non e' supportato da Windows " & _
"Sockets per ambienti Windows a 32 bit."
MsgBox szBuf, vbExclamation
SocketsInitialize = False
Exit Function
End If
If WSAD.wMaxSockets < MIN_SOCKETS_REQD Then
szBuf = "This application requires a minimum of " & _
Trim$(Str$(MIN_SOCKETS_REQD)) & " socks supportati."
MsgBox szBuf, vbExclamation
SocketsInitialize = False
Exit Function
End If
SocketsInitialize = True
End Function

'--end block--'

Codice del Form
Aggiungete ad una form un command button (command1), due text box (Text3, Text4)
e sei text box come array di controlli (Text1(0) - Text1(5)).
Le label sono opzionali
Aggingete il seguente codice al command button:
--------------------------------------------------------------------------------
Option Explicit
Private Sub Command1_Click()
Dim ECHO As ICMP_ECHO_REPLY
Dim pos As Integer
'Pingate un indirizzo IP, passando l'indirizzo e una struttare ECHO

Call Ping("209.68.48.118", ECHO)
'visualizzate il risultato dalla struttura ECHO

Text1(0) = GetStatusCode(ECHO.status)
Text1(1) = ECHO.Address
Text1(2) = ECHO.RoundTripTime & " ms"
Text1(3) = ECHO.DataSize & " bytes"
If Left$(ECHO.Data, 1) <> Chr$(0) Then
pos = InStr(ECHO.Data, Chr$(0))
Text1(4) = Left$(ECHO.Data, pos - 1)
End If
Text1(5) = ECHO.DataPointer
End Sub

'--end block--'

Prerequisiti:
una connessione di Accesso Remoto attiva
-----------------------------------------------
Con questa routine potrete eseguire un Ping su qualsiasi
indirizzo IP. Ping e' uno strumento che consente di verificare
una connessione a livello IP. Quando si fanno delle ricerche
di errore, il comando Ping viene usato per inoltrare una
richiesta ECHO ICMP ad una determinata macchina usando il
nome della macchina o il suo indirizzo IP.
Usate Ping ogni volta che volete verificare se un determinato
computer e' in grado di collegarsi alla rete TCP/IP e di
utilizzare le risorse di rete. E' possibile usare il comando
Ping anche per isolare problemi hardware delle reti e
configurazioni non compatibili. Di solito e' sempre buono
verificare che ci sia un collegamento tra un computer locale
e un computer remoto utilizzando inizialmente il comando Ping
con l'indirizzo del computer remoto al quale ci si vuole
collegare. Provate a Pingare il computer remoto per vedere se
risponde, perche' questo e' il modo piu' semplice. Il concetto
in VB consiste in passare ad una routine l'indirizzo IP da
pingare e un messaggio a 32bit che il ping dovrebbe
ritornare in caso di successo. Questa routine non funziona
con domini che hanno un nome; funziona solo se gli viene
passato l'indirizzo IP del computer remoto, e non il suo
nome. Per testare questa routine e' necessario essere
collegati ad una rete locale o ad Internet. Non voglio far
credere di sapere molto sulle reti... questo codice
(contenuto in un unico file bas) mi e' stato recapitato senza
firma. Se l'autore e' conosciuto sarei felice di conoscere
chi sia in modo da potergli attribuire i giusti crediti.
Inoltre, i commenti sono solo quelli dell'autore stesso, con
qualche descrizione presa dall'MSDN.
In fine, giusto per tenere i messaggi di errore corti , li
ho divisi in piu' linee quando necessario. Modulo BAS
Aggiungete il seguente codice ad un modulo Standard:










( remoteping.html )- by Paolo Puglisi - Modifica del 17/12/2023